Phone: 0902937088 
Đại lý  Vaisala VIETNAM
 

Code : HMT3604A22BCH1B2BF5A3G

HMT364 Humidity and Temperature Transmitter
For high pressurized processes

Parameters : RH+T

Display on transmitter cover

2 analog output channels (Ch1 + Ch2) 4... 20 mA

RH (0... 100%RH)

T (0...+100°C)

Interface cable connection : Conduit fitting NPT1/2"

Ex certification and issuer : ATEX (VTT), Ex ia IIC T4

User's guide : English

Probe and cable length : 5m

Sensor type: HUMICAP 180R

Sensor protection : Sintered stainless steel filter

Probe installation accessories : NPT Fitting Body

1

Vaisala

Code : HMT3604A22BCH1B2BF5A3G

HMT364 Humidity and Temperature Transmitter
For high pressurized processes

Parameters : RH+T

Display on transmitter cover

2 analog output channels (Ch1 + Ch2) 4... 20 mA

RH (0... 100%RH)

T (0...+100°C)

Interface cable connection : Conduit fitting NPT1/2"

Ex certification and issuer : ATEX (VTT), Ex ia IIC T4

User's guide : English

Probe and cable length : 5m

Sensor type: HUMICAP 180R

Sensor protection : Sintered stainless steel filter

Probe installation accessories : NPT Fitting Body

1

Vaisala

Code : HMT3604A22BCL1B2BF5A3G

HMT364 Humidity and Temperature Transmitter
For high pressurized processes

Parameters : RH+T

Display on transmitter cover

2 analog output channels (Ch1 + Ch2) 4... 20 mA

RH (0... 100%RH)

T (0...+180°C)

Interface cable connection : Conduit fitting NPT1/2"

Ex certification and issuer : ATEX (VTT), Ex ia IIC T4

User's guide : English

Probe and cable length : 5m

Sensor type: HUMICAP 180R

Sensor protection : Sintered stainless steel filter

Probe installation accessories : NPT Fitting Body

1

Vaisala

Vaisala Vietnam

Code: DMT152 A1DCE1XA33EA1X

Low Dewpoint Transmitter

 

Vaisala Vietnam

Humidity and Temperature Transmitter
code: HMT330 7S0B021XCAN100A41CKAAA1
Transmitter Type: HMT337 for high humidities
Probe cables: Probe 2m +180C; No Additional Temperature Probe
Calculations: Cod RH+T+Td+a+Tw+x+h+pws; No Display
Power supply: Universal AC-Power (100...240VAC)
Signal Output: Analog Output 4...20mA
Analog output signals for Ch1: Channel 1 Special
Analog output signals for Ch2: Channel 2 T (Range See Below)
No Analog output signals for Ch3
Analog output range for temperature: 0...+180C
Output Units: Metric Units
No Option for module slot 1; No Option for module slot 2
Cable bushings: Sealed Cable Gland M20x1.5
Transmitter installation: DIN Rail Clips with  Installation Plate
Humidity sensor: General purpose HUMICAP180
Sensor protection: Sintered Filter AISI 316L  HM47280
Installation kit for probe: Swagelok for 12mm Probe 1/2" NPT Thread; No Operating manual language
No Calibration Contract ISO9001 Calibration
No Maintenance Contract

Bình chọn sản phẩm: (5.0 / 1 Bình chọn)