liên hệ: Ms Liên
Email: lien.ans@ansvietnam.com
Cell phone: 0902937088
Vaisala việt nam
Vaisala việt nam
Cảm biến nhiệt độ và độ ẩm
Bộ đo nhiệt độ và độ ẩm
Bộ điều khiển nhiệt độ và độ ẩm
Thiết bị đo điểm sương
% Finland Origin | Vaisala Vietnam | Code: HMT330-7U3D111XCAX100B0EACBAA1 |
Cable length: 10 Meter cable =) (Cuộn Tròn Được) | ||
Type: HUMICAP® Humidity and Temperature Transmitter | ||
Additional temperature probe 10 m cable | ||
Parameters: RH+T+Td+Tdf+a+x+Tw+ppm+pw+pws+h+dT | ||
Display: Graphic LCD with backlight | ||
Power supply: 10..35 VDC, 24 VAC with galvanic isolation | ||
Analog output channel (Ch1&Ch2&Ch3): 4... 20 mA | ||
Cable bushings: Conduit fitting NPT1/2" | ||
Composite sensor with chemical purge HUMICAP180RC | ||
PPS plastic grid & stainless steel netting spare:DRW010281SP | ||
Duct installation kit (for RH probe): item: 210697 | ||
100% Finland Origin | Vaisala Vietnam | Code: HMT120-KD1A2E12A2C0Z |
Type: HUMICAP® Humidity and Temperature Transmitter | ||
Output parameters: Humidity and temperature output | ||
Transmitter type: Remote probe with 10 m cable, Display | ||
Output signal: 4...20 mA, 2-wire loop-powered | ||
Sensor protection: Plastic grid with PTFE filter | ||
Installation kit for probe: Duct installation kit (215619) | ||
Cable bushings: Conduit fitting NPT 1/2" | ||
100% Finland Origin | Vaisala Vietnam | Code: HMT330 3F0A001BCAC100A0AACBAA1 |
Cable length: 5 Meter cable, +80°C(Cuộn Tròn Được) | ||
Type: Humidity and Temperature Transmitter | ||
No additional temperature probe,Parameters: RH+T, No display | ||
Power supply: 10...35 VDC , 24 VAC | ||
Analog output channel (Ch1&Ch2&Ch3): 4... 20 mA. (0... 100%RH), T: -40...+80°C | ||
Output units: Metric, Cable gland M20 x 1.5, Normal mounting | ||
General purpose and high chemical concentrations HUMICAP180R | ||
PPS plastic grid & stainless steel netting spare: DRW010281SP | ||
Installation kit for probe: Duct installation kit (item: 210697) | ||
Operating manual language: English | ||
No maintenance and repair contract | ||
100% Finland Origin | Vaisala Vietnam | Probe HM41 |
Hand-Held Humidity and Temperature meter Standard | ||
100% Finland Origin | Vaisala Vietnam | Probe HM42 |
Hand-Held Humidity and Temperature Meter with HM42PROBE | ||
100% Finland Origin | Vaisala Vietnam | Probe HM45 |
Hand-Held Humidity and Temperature Meter Remote Probe with Handle | ||
100% Finland Origin | Vaisala Vietnam | Probe HM46 |
Hand-Held Humidity and Temperature Meter with HM46PROBE | ||
100% Finland Origin | Vaisala Vietnam | Model: HMT3601A22BCC1C7BA5A10 |
Vaisala HUMICAP® Humidity and Temperature Transmitter | ||
Transmitter type: HMT361, Parameters: RH+T | ||
Display on transmitter cover | ||
Number of analog outputs: 2 analog output channels (Ch1 + Ch2), 4... 20 mA, Analog output (Ch1 & Ch2): RH (0... 100%RH), T (choose range in next section) | ||
Analog output range for temperature: 0...+60°C (+32...+140°F) | ||
Output units: Metric | ||
Cable gland M20x1.5 for cable diameters 10 ... 15 mm | ||
Ex certification and issuer: TIIS (Japan) | ||
User's guide: English | ||
Probe and cable length: HMP361(max +60°C) | ||
Sensor type: HUMICAP 180R | ||
Sensor protection: PPS plastic grid & stainless steel netting (recommended choice) - spare: DRW010281SP | ||
100% Finland Origin | Vaisala Vietnam | Code: HMT311A51BCC14BAAA1A2 |
Vaisala HUMICAP® Humidity and Temperature Transmitter | ||
Parameters: RH+T, Standard mounting plate, | ||
Power supply: 24 VDC | ||
Analog output channel: 4... 20 mA & RS232C | ||
Cable connector: 8-pole connector with 5m cable | ||
Probe type: Fixed | ||
100% Finland Origin | Vaisala Vietnam | Spare probe for GMM222/GMT222 |
Model: GMP222C0N0 | ||
Measurement range: 0…2000 ppm CO2 | ||
Reserved: None | ||
Proble installation accessories: none | ||
Field Check Adapter:none | ||
100% Finland Origin | Vaisala Vietnam | Model: DMT143N1C1A1A5A0ASX |
Dewpoint Transmitter | ||
Type: DMT143 | ||
Td: -80 - 20 0C, Output:40-20 mA, Pressure setting: 1 bar | ||
Cable: 10 Meter | ||
100% Finland Origin | Vaisala Vietnam | Code: DMT242-A1A1A2J |
DMT242 - A1A1A2J | ||
A: Dew point range for analog output: -80…+20 °C Td, DRYCAP®180M | ||
1: Analog Output Cable : No cable - connector only | ||
A: Pressure setting for optimized accuracy: 1 bar abs | ||
1: Sensor protection: Stainless steel sintered filter (38 um) | ||
A: PC accessories: None | ||
2: Installation accessories: Sampling cell, swagelok 1/4" male connectors | ||
J: User's guide: Japanese | ||
100% Finland Origin | Vaisala Vietnam | Type: HMT337 |
Order code: HMT330 7S1D001BXCX103A05AABAA1 | ||
Serial No.: F0720117 | ||
Supply 10…35 VDC, Output 3*4…20mA | ||
CH1: RH 0…100 %RH, CH2: Td -40…80 0C | ||
CH3: T -50…60 0C | ||
100% Finland Origin | Vaisala Vietnam | Type: DTR503 |
Serial No.: F072 | ||
100% Finland Origin | Vaisala Vietnam | Replaced by: DMT143 |
Completed code: DMT143 G1C1A1C3A0ASX | ||
G½ mechanical connection, 4…20 mA | ||
Analog output scaling -80…+20 °C Td | ||
Alarm LED set point off, 3 Meter cable | ||
Pressure setting for optimized accuracy 5 bar | ||
(DMT142 has been ended) | ||
100% Finland Origin | Vaisala Vietnam | DSS70A |
Sampling System | ||
100% Finland Origin | Vaisala Vietnam | 210801 |
Filter for DSS70A | ||
100% Finland Origin | Vaisala Vietnam | Dewpoint and Pressure Transmitter |
Model: DPT146B1DCC100A0X | ||
100% Finland Origin | Vaisala Vietnam | Humidity meter |
Model: HMD82D | ||
100% Finland Origin | Vaisala Vietnam | Correct model: HM70-D0A1A0AB |
(HM70-D0A1B0AB) | ||
Hand-held Humidity and Temperature Meter | ||
100% Finland Origin | Vaisala Vietnam | Correct model: DMT242-B2A1A0B |
(DMT242-B2-20-1A0B) | ||
Hand-held Humidity and Temperature Meter | ||
100% Finland Origin | Vaisala Vietnam | Hand-held Dewpoint Meter |
Model: DM70-D0A0A0B1 | ||
100% Finland Origin | Vaisala Vietnam | Correct Code: DM70 B5B2A0B1 |
(DM70 B5B2A3B1) | ||
100% Finland Origin | Vaisala Vietnam | Code: DMT340 6Q0K1B121A1A001A2D6K0C0 |
100% Finland Origin | Vaisala Vietnam | GMM221 L 1N0A4A0C0B |
Rang: 0 - 10%, Output : 4-20mA, Cable 2m | ||
100% Finland Origin | Vaisala Vietnam | Replaced by: HMP360 1A5A1A7 |
Note: The order code has changed a little (the second last digit: Installation Kit; it used to be 0=No kit, but now it’s A=No kit), | ||
(Code: HMP3601A5A107 | ||
Serial Numbel: J0940005) | ||
100% Finland Origin | Vaisala Vietnam | Replaced by: HMP360 1A5A1A7 |
Note: The order code has changed a little (the second last digit: Installation Kit; it used to be 0=No kit, but now it’s A=No kit), | ||
(Code: HMP3601A5A107 | ||
Serial Numbel: J0940005) | ||
100% Finland Origin | Vaisala Vietnam | Digital Barometer |
Model: PTB330B1JAHAACEA0A0B | ||
100% Finland Origin | Vaisala Vietnam | Model: HMT330 7S1D003BCAE100A05DABAA1 |
Note: Please check that this code is correct, the namelate picture was a bit unclear… | ||
100% Finland Origin | Vaisala Vietnam | Replaced by: HMT360 4D22CHD1A2BE5A3K |
Note: The below mentioned order code is from the old HMT364 model (we changed the HMT360 series products at the end of 2007). | ||
Please check your customer’s needs regarding the options 10 (I guess the correct choice would be 2) and 16 in the new order form | ||
(Humidity and temperature transmitter: | ||
HMT364 D22CHD1A1BE1A3A1 | ||
Sn.: C1740004 EEx ia IIC T5 Ui=28V Ii=100mA VTT Ex-99.E.005X Ci=48nF Li=22uH) | ||
100% Germany / Finland Origin | VAISALA Vietnam | HM40 C2BB(HM40C2BB) |
[including HM42PROBE (thin 4 mm stainless steel measurement probe)] | ||
100% Germany / Finland Origin | VAISALA Vietnam | HM42PROBE (probe only) |
100% Germany / Finland Origin | VAISALA Vietnam | Calibration adapter for HM42 and HMP42 Probe, for use with HMK15 and HMK11 Calibrators |
100% Finland Origin | Vaisala Vietnam | Probe |
Model: HMP155 D2AB21A0A1A1A0A | ||
100% Filand Origin | Vaisala Vietnam | HMP231 is obsoleted, The replacing model would be HMT331 1A0B001BCAF100A01CABAA1 |
100% Finland Origin | Vaisala Vietnam | Vaisala HUMICAP® Hand-Held Humidity and Temperature Meter HM70 |
Code: HM70 - F0E1A4AB , included: | ||
- MI70 Indicator with rechargeable battery (all AC adapters) – weight 400 gram | ||
- Probe HMP77B (chemical purge and sensor preheating) – weight: 500 gram | ||
- Connection cable to HMT330 and HMT120/130 (211339) – weight 300 gram | ||
- English manual | ||
100% Filand Origin | Vaisala Vietnam | DMT340 - 6Q0K1B121A1A201A2D6K0C0 : RS-485 Serial Interface |
100% Filand Origin | Vaisala Vietnam | DMT340 - 6Q0K1B121A1A401A2D6K0C0 LAN (ethernet) interface + 2 m cable (RJ45) |
100% Filand Origin | Vaisala Vietnam | DMT340 - 6Q0K1B121A1A201A2D6K0C0 : RS-485 Serial Interface |
100% Filand Origin | Vaisala Vietnam | DMT340 - 6Q0K1B121A1A401A2D6K0C0 LAN (ethernet) interface + 2 m cable (RJ45) |
100% Finland Origin | Vaisala Vietnam | HM42 Humidity and Temperature Meter with thin 4 mm remote probe |
100% Finland Origin | Vaisala Vietnam | Correct: MI70B10 |
B: Indicator Type: Rechargeable with Euro AC-adapter | ||
1: Special features – standard | ||
0: no indicator accessories | ||
(MI70J10) | ||
100% Finland Origin | Vaisala Vietnam | Replaced by: HM70A0E1A0AA |
The package includes: | ||
- HMP77B humidity and temperature probe: 0…100 %RH, -70...+180 °C (-94...+356 °F) | ||
- Chemical purge and sensor preheat features | ||
- Calibration certificate (ISO9001 compliant, traceable to NIST) | ||
(HMP77B) | ||
100% Finland Origin | Vaisala Vietnam | Code: HM70 - B0E1A0DB |
Included the HMP77B probe and indicator MI70. | ||
- MI70 hand-held indicator | ||
- HMP77B humidity and temperature probe: 0…100 %RH, -70...+180 °C (-94...+356 °F) | ||
- Calibration certificate (ISO9001 compliant, traceable to NIST) | ||
- Rechargeable battery pack and universal AC adapter | ||
- MI70LINK software with USB cable | ||
- Professional carrying case | ||
- User's Guide in English | ||
Note: The HMP77B probe is ordered in the configuration code of HM70 | ||
(MI70J10 | ||
HMP77B) | ||
100% Germany / Finland Origin | VAISALA Vietnam | Fixed Price Repair for DMT340 Transmitter |
Part no. DMT340SERV | ||
Note: Sorry but the DRW221587 is not a sales item. If it is question of a broken transmitter which would need a new probe, you should contact our Service Center for repair of the instrument | ||
(Probe (5m, +180C) DRW221587) | ||
100% Finland Origin | Vaisala Vietnam | Correct Model:PTU3031B01A1BCPK1A0A1AAB1B0A |
Correct: Humidity and Temperature Transmitter PTU3031B01A1BCPK1A0A1AAB1B0A | ||
Pressure range: 500...1100 hPa, Probe cable length : 2 m cable, +80 °C, no additional temperature probe, Graphical display with keypad. Power supply: 10...35 VDC, 24 VAC | ||
Output signal: RS232C + Analog outputs (Ch1 & Ch2, optional Ch3), Cable gland M20*1.5 | ||
Pressure fitting: Barbed fitting for 1/8" hose | ||
Humidity sensor: General purpose and high chemical concentrations - HUMICAP180R | ||
Sensor protection: PPS plastic grid & stainless steel netting, spare: DRW010281SP | ||
Probe installation accessories : Duct Installation kit, item 215003 | ||
(PTU3031B1A1BCPK1A0A1AB1B0A) | ||
100% Finland Origin | Vaisala Vietnam | Model: DM70K0A0A0B1 |
Hand-held Dewpoint Meter, Indicator type: alkaline batteries only, no indicator accessories | ||
Probe type: DMP74A -40…+60°C Td, no accessories, no connection cable, no carrying case** | ||
100% Finland Origin | Vaisala Vietnam | Model:HMT3305M0B121BCAE111G0CCGBEA1 |
Humidity and Temperature Transmitter | ||
Cable length: 5 m cable =) Cuộn Tròn Được | ||
No additional temperature probe | ||
Parameters: RH+T+Td+Tdf+a+x+Tw+ppm+pw+pws+h+dT | ||
Display: Graphic LCD with backlight | ||
Power Supply: Universal AC-power (100...240 VAC) | ||
Cable bushings: Bushing Set (Cable gland M20 x 1.5 and Conduit fitting NPT1/2") | ||
Humidity sensor type with chemical purge function, spare: HUMICAP180RC | ||
Sensor protection: Sintered stainless steel filter, spare: HM47280SP | ||
Installation kit for probe: Mounting flange, item: 210696 | ||
PC Accessories: MI70LINK software for Windows® with USB service cable, item: 219916 | ||
100% Finland Origin | Vaisala Vietnam | Correct Code:HMT3307S0A011BBAB120A0AACBAA |
(HMT3307S0A01BBAB120A0AACBAA) | ||
Humidity and Temperature Transmitter | ||
Cable length: 2 m cable =) Cuộn tròn được | ||
Parameters: RH+T, Signal output : 4... 20 mA. | ||
Power supply: 10..35 VDC, 24 VAC with galvanic isolation, | ||
Option for module slot 1: RS-485 serial interface (galvanically isolated) | ||
Cable bushings: Cable gland M20 x 1.5 | ||
Humidity sensor type: General purpose and high chemical concentrations HUMICAP180R | ||
Sensor protection: PPS plastic grid & stainless steel netting DRW010281SP | ||
Installation kit for probe: Duct installation kit, item: 210697 | ||
100% Finland Origin | Vaisala Vietnam | Model: D08A-24TS2 |
100% Finland Origin | Vaisala Vietnam | Model: DM70F1B1A4B |
Portable dewpoint meter | ||
Indicator type :rechargable with all AC adapters | ||
indicator Accessories: MI70LINK software with RS232 cable (MI70LINK) | ||
Probe type: DMP74B -60…+20°C Td | ||
Pro accessories: sampling cell DSC74 | ||
Connection Cable to a Transmitter: no | ||
Carrying Case : soft carrying case (MI70SOFTCASE) | ||
100% Finland Origin | Vaisala Vietnam | Model: 213107SP |
10 m extension cable for the MI70 probes | ||
100% Finland Origin | Vaisala Vietnam | Model: HMD82 |
Humidity and Temperature Transmitter, 2-wire HMD82 | ||
100% Finland Origin | Vaisala Vietnam | Model: HMD82 |
Humidity and Temperature Transmitter, 2-wire HMD82 |