hãy liên hệ với chúng tôi để có giá tốt nhất.

0902.937.088 [ MS Liên ]         Skype: lientran87

 

 

 

Humidity and Temperature Transmitter
Code: HMT330 7S1D001BBBB211A15ACBBA1
Transmitter type: HMT337 for high humidities
Probe cables: Probe 2m +180C
Additional temperature probe: T-probe, 2m, -70..+180°C 1/4 DIN Class B; Calculations: Cod RH+T+Td+a+Tw+x+h+pws With warmed RH-pro+T-pro ; No Display
Power supply: Standard (10...35V,24VAC)
Signal output: Analog Output 4...20mA
Analog output signals for Ch1: 0...100%RH
Analog output signals for Ch2: 0...100%RH
Analog output signals for Ch3: 0...100%RH
Analog output range for temperature: Temperature Range -40...+60C ; Output units: Non Metric Units
Option for module slot 1: Relay Module
Option for module slot 2: Relay Module
Cable bushings: Sealed Cable Gland M20x1.5
Transmitter installation: Wall Mounting Kit
Humidity sensor: Heated composite sensor HUMICAP180C
Sensor protection: PPS Grid with Steel Netting
Installation kit for probe: Duct Installation Kit For HMT333 and HMT337 ; User´s Guide HMT330 English
PC Accessories: RS232 Serial Interface Cable with D9 Female Connector ; No Calibration Contract ISO9001 Calibration
No Maintenance Contract

 

Code: HMT330 7S0A001BCAE200A0AACBCA1
Humidity and Temperature Transmitter
Transmitter type: HMT337 for high humidities
Probe cables: 2m +180C; No Additional temperature probe
Calculations: Code RH+T, No Display
Power supply: Standard (10...35V,24VAC)
Signal output: Analog Output 4...20mA
Analog output signals for Ch1: 0...100%RH
Analog output signals for Ch2: Temperature Range -40...+180C
No Analog output signals for Ch3
Output units: Non Metric Units
Option for module slot 1 &2: No Module
Cable bushings: Sealed Cable Gland M20x1.5
No Transmitter installation
Humidity sensor: General purpose HUMICAP180R
Sensor protection: PPS Grid with Steel Netting
Installation kit for probe: Duct Installation Kit For HMT333 and HMT337 ; User´s Guide HMT330 English
PC Accessories: MI70LINK PC Software with RS232 Serial Cable with D9 Female Connector
No Calibration Contract ISO9001 Calibration
No Maintenance Contract

 

 

Humidity and Temperature Transmitter HMT330-3E0A001BCAX100B01ACBAA1

HMT333 for general use, Probe cables 2m, No Temperature Probe

Calculations: Code RH+T, no display, Power supply : Standard (10...35V,24VAC); Signal output: Analog Output 4...20mA,

Analog output signals for Ch1: Channel 1 RH (0...100%RH)

Analog output signals for Ch2: Temperature Range Special 0...50°C

Analog output signals for Ch3: No Analog Outputs

Output units: Metric Units

Option for module slot 1/ slot 2: No Module

Cable bushings: Cond Uit Fitting NPT 1/2"

Transmitter installation: No Installation Kit

Humidity sensor: General purpose HUMICAP180

Sensor protection: PPS Grid with Steel Netting

Installation kit for probe: Duct Installation Kit For HMT333 and HMT337

 

 

Humidity and Temperature Transmitter

Code: HMT330 7S1D011BXAA100A45CQBAA1

Transmitter type: HMT337 for high humidities

Probe cables: Probe 2m +180C

Additional temperature probe: T-probe, 2m, -70..+180°C 1/4 DIN Class B; Calculations: Cod RH+T+Td+a+Tw+x+h+pws With warmed RH-pro+T-pro ; No Display

Power supply: Standard with Galvanic Isolation Module

Signal output: Analog Output 4...20mA

Analog output signals for Ch1: 0...100%RH

Analog output signals for Ch2: Special – pls confirm and make clear as order ; No Analog output signals for Ch3

Analog output range for temperature: no T range

Output units: Metric Units; No Option for module slot 1&2

Cable bushings: Sealed Cable Gland M20x1.5

Transmitter installation: DIN Rail Clips with  Installation Plate

Humidity sensor: Heated composite sensor HUMICAP180C

Sensor protection: Sintered Filter AISI 316L  HM47280

Installation kit for probe: Swagelok for 12mm Probe 1/2" NPT Thread ; User´s Guide HMT330 English

No PC Accessories ; No Calibration Contract ISO9001 Calibration

 

Vaisala Vietnam

Code: HMT330 7S1D001BXAA100A1DAABAA1

Humidity and Temperature Transmitter; Transmitter type: HMT337 for high humidities; Probe cables: Probe 2m +180C

Additional temperature probe: 2m, -70..+180°C 1/4 DIN Class B

Calculations: Cod RH+T+Td+a+Tw+x+h+pws With warmed RH-pro+T-pro; No display, power supply : Standard (10...35V,24VAC)

Signal output: Analog Output 4...20mA; Analog output signals for Ch1: 0...100%RH; Analog output signals for Ch2: Special (pls confirm as placing order); Output units: Metric Units; Option for module slot 1&2: no module; Cable bushings: Sealed Cable Gland M20x1.5; Transmitter installation: Wall Mounting Kit; Humidity sensor: Heated composite sensor; Sensor protection: PPS Grid with Steel Netting; No Installation Kit, No Accessories

Bình chọn sản phẩm: (5.0 / 1 Bình chọn)