hãy liên hệ với chúng tôi để có giá tốt nhất.
0902.937.088 [ MS Liên ] Skype: lientran87
Humidity and Temperature Transmitter
Code: HMT330 7S1D001BBBB211A15ACBBA1
Transmitter type: HMT337 for high humidities
Probe cables: Probe 2m +180C
Additional temperature probe: T-probe, 2m, -70..+180°C 1/4 DIN Class B; Calculations: Cod RH+T+Td+a+Tw+x+h+pws With warmed RH-pro+T-pro ; No Display
Power supply: Standard (10...35V,24VAC)
Signal output: Analog Output 4...20mA
Analog output signals for Ch1: 0...100%RH
Analog output signals for Ch2: 0...100%RH
Analog output signals for Ch3: 0...100%RH
Analog output range for temperature: Temperature Range -40...+60C ; Output units: Non Metric Units
Option for module slot 1: Relay Module
Option for module slot 2: Relay Module
Cable bushings: Sealed Cable Gland M20x1.5
Transmitter installation: Wall Mounting Kit
Humidity sensor: Heated composite sensor HUMICAP180C
Sensor protection: PPS Grid with Steel Netting
Installation kit for probe: Duct Installation Kit For HMT333 and HMT337 ; User´s Guide HMT330 English
PC Accessories: RS232 Serial Interface Cable with D9 Female Connector ; No Calibration Contract ISO9001 Calibration
No Maintenance Contract
Code: HMT330 7S0A001BCAE200A0AACBCA1
Humidity and Temperature Transmitter
Transmitter type: HMT337 for high humidities
Probe cables: 2m +180C; No Additional temperature probe
Calculations: Code RH+T, No Display
Power supply: Standard (10...35V,24VAC)
Signal output: Analog Output 4...20mA
Analog output signals for Ch1: 0...100%RH
Analog output signals for Ch2: Temperature Range -40...+180C
No Analog output signals for Ch3
Output units: Non Metric Units
Option for module slot 1 &2: No Module
Cable bushings: Sealed Cable Gland M20x1.5
No Transmitter installation
Humidity sensor: General purpose HUMICAP180R
Sensor protection: PPS Grid with Steel Netting
Installation kit for probe: Duct Installation Kit For HMT333 and HMT337 ; User´s Guide HMT330 English
PC Accessories: MI70LINK PC Software with RS232 Serial Cable with D9 Female Connector
No Calibration Contract ISO9001 Calibration
No Maintenance Contract
Humidity and Temperature Transmitter HMT330-3E0A001BCAX100B01ACBAA1 |
HMT333 for general use, Probe cables 2m, No Temperature Probe |
Calculations: Code RH+T, no display, Power supply : Standard (10...35V,24VAC); Signal output: Analog Output 4...20mA, |
Analog output signals for Ch1: Channel 1 RH (0...100%RH) |
Analog output signals for Ch2: Temperature Range Special 0...50°C |
Analog output signals for Ch3: No Analog Outputs |
Output units: Metric Units |
Option for module slot 1/ slot 2: No Module |
Cable bushings: Cond Uit Fitting NPT 1/2" |
Transmitter installation: No Installation Kit |
Humidity sensor: General purpose HUMICAP180 |
Sensor protection: PPS Grid with Steel Netting |
Installation kit for probe: Duct Installation Kit For HMT333 and HMT337 |
Humidity and Temperature Transmitter |
Code: HMT330 7S1D011BXAA100A45CQBAA1 |
Transmitter type: HMT337 for high humidities |
Probe cables: Probe 2m +180C |
Additional temperature probe: T-probe, 2m, -70..+180°C 1/4 DIN Class B; Calculations: Cod RH+T+Td+a+Tw+x+h+pws With warmed RH-pro+T-pro ; No Display |
Power supply: Standard with Galvanic Isolation Module |
Signal output: Analog Output 4...20mA |
Analog output signals for Ch1: 0...100%RH |
Analog output signals for Ch2: Special – pls confirm and make clear as order ; No Analog output signals for Ch3 |
Analog output range for temperature: no T range |
Output units: Metric Units; No Option for module slot 1&2 |
Cable bushings: Sealed Cable Gland M20x1.5 |
Transmitter installation: DIN Rail Clips with Installation Plate |
Humidity sensor: Heated composite sensor HUMICAP180C |
Sensor protection: Sintered Filter AISI 316L HM47280 |
Installation kit for probe: Swagelok for 12mm Probe 1/2" NPT Thread ; User´s Guide HMT330 English |
No PC Accessories ; No Calibration Contract ISO9001 Calibration |
Vaisala Vietnam |
Code: HMT330 7S1D001BXAA100A1DAABAA1 |
Humidity and Temperature Transmitter; Transmitter type: HMT337 for high humidities; Probe cables: Probe 2m +180C |
|
Additional temperature probe: 2m, -70..+180°C 1/4 DIN Class B |
|
Calculations: Cod RH+T+Td+a+Tw+x+h+pws With warmed RH-pro+T-pro; No display, power supply : Standard (10...35V,24VAC) |
|
Signal output: Analog Output 4...20mA; Analog output signals for Ch1: 0...100%RH; Analog output signals for Ch2: Special (pls confirm as placing order); Output units: Metric Units; Option for module slot 1&2: no module; Cable bushings: Sealed Cable Gland M20x1.5; Transmitter installation: Wall Mounting Kit; Humidity sensor: Heated composite sensor; Sensor protection: PPS Grid with Steel Netting; No Installation Kit, No Accessories |